Target housing stock:

  • Typical UK house types, such as family semi-detached and terraced houses with characteristics around the average: 3 bedroom, 90 m2, 100 mm loft insulation, partial double glazing and a central heating system

Target carbon emission reductions (from an individual house):

  • Relative target of more than 60% carbon savings from an established baseline, or if not tangible
  • Absolute target of 2 tCO2 total house emissions or 0.5 tCO2 per occupant (if occupancy pattern deviates considerably from the average)

Means for achieving the GH standard:

Roof/loft

  • Insulation
 

 

300 mm mineral wool or ZODP equivalent
(Remark: minimum at joists; preferred at rafter level (when re-roofing)

  • Air-tightness
  5 m3/m2/h @ 50pa
  • Ventilation
  Minimum options: Passive stack and humidity sensors or Mechanical
Preferred option: Whole house mechanical ventilation with heat recovery and low fan power (1 W/l/s)
  • Roof solar systems
  Solar Hot Water and/or Solar PV
(Remark: depends on orientation and roof space; preferred full roof integration if re-roofing

Walls

  • Insulation
 

 

For semi detached and detached: 150 mm external or internal insulation
For terraced: 150 mm internal or external insulation at the back and dry lining and better windows at the front.


Windows

  • Performance
 

 

1.5 W/m2K at worst for the whole window; daylight transparency – 60%

  • Quality
  Durable, secure, sympathetic to context and from sustainable materials source
(Remark: secondary double glazing may be acceptable in difficult cases)

Floor

  • Insulation
 

 

Proper floor and perimeter insulation


Hot water and Heating

 

   
  • Specification
  Minimum option: Grade A boiler
Preferred options: innovative solutions such as biomass, micro CHP, Heat pumps ; Solar thermal store; electric (where demand is very low)
(Remark: not combi boiler if SHW also installed; Heat pumps if off-gas grid)
  • Controls
  Comprehensive and user friendly controls, e.g. CHESS
  • Sustainability
  Water conservation measures

Electricity demand

  • Appliances
 

 


Grade A / A+ / A++ only

  • Lighting
  Dedicated CFLs to fixed points

Energy consumption patterns:

  • Awareness
  User displays of electricity consumption
  • Behaviour
  Education and user manuals